For new natural ester fluid, Table 1 of ASTM D6871-26 names three breakdown tests: power-frequency breakdown with disk electrodes by ASTM D877/D877M, power-frequency breakdown with VDE electrodes at two gap spacings by ASTM D1816, and impulse breakdown across a needle-to-sphere gap by ASTM D3300.

ProvenanceASTM D6871-26 supports data record tests.insulating-liquid-dielectric-breakdown.astmd6871.methods, which is cited on the entry Insulating Liquid Dielectric Breakdown.SOURCEASTM D6871-26ASTM D6871-26Licensed standard, clause Table 1DATA RECORDtests.insulating-liquid-dielectric-breakdown.astmd6871.methodstests.insulating-liquid-..Verified 2026-10-24ENTRYInsulating Liquid Dielectric BreakdownInsulating Liquid Dielec..No revisions
Provenance. Where this record comes from and where it is used: the cited source, the record itself and the entry that cites it.
Provenance: the chain from source to entry.
StepItemDetail
SourceASTM D6871-26Licensed standard, clause Table 1
Data recordtests.insulating-liquid-dielectric-breakdown.astmd6871.methodsVerified 2026-10-24
EntryInsulating Liquid Dielectric BreakdownNo revisions
Subject
Insulating Liquid Dielectric Breakdown (Test methods)
Kind
Method fact
Source
ASTM D6871-26, clause Table 1, Natural (Vegetable Oil) Ester Fluids Used in Electrical Apparatus, ASTM International. Publisher page

History

Every recorded change to this data record, oldest first.
DateChange
2026-10-24created
2026-10-24review_status unreviewed -> software_reviewed
2026-10-27hold lifted

Cite this page

Cite the governing standard for the fact itself; cite this page as the finding aid.

"Data record tests.insulating-liquid-dielectric-breakdown.astmd6871.methods." Insulating Fluid Reference. 2026-10-27. https://www.insulatingfluidreference.com/data/tests.insulating-liquid-dielectric-breakdown.astmd6871.methods/.